Chromated, water reducible, chemically cured.
Unit of Measure

Product Information

Specifications

N/A BMS 10-11AB TYPE I CLASS A GRADE E
BAMS 565-001C GRADE B CATEGORY 2 TYPE 1
RMS118H TYPE I CLASS L and M

Reducer

N/A Distilled or Deionized Water (˜150% reduction)

Mix Ratio

N/A 2 parts 44GN060 base by volume to
1 part 44GN060CAT catalyst by volume to
4.5 parts water by volume (150% ± 10% reduction)
Pot Life1 N/A 6 hour

Initial Viscosity (# 2 EZ Zahn Cup)

N/A 20 ± 2 seconds

Initial Viscosity (#2 Ford Cup)

N/A 31 to 39 seconds

Induction Time

N/A None Required

Application Dry Film Thickness

N/A 0.5 to 0.7 mil

Storage Stability

N/A 9 months from date of manufacture when stored indoors between 40 ºC - 100 ºF

Kit Size

Kit Size GK (44GN060 Base)

N/A 85 oz2.5 L

Kit Size GK (44GN060CAT)

N/A 43 oz1.3 L

Kit Size GK (Deionized (D.I) Water)

N/A 192 oz5.7 L

Kit Size 1GK (44GN060 Base)

N/A 32 oz946 mL

Kit Size 1GK (44GN060CAT)

N/A 16 oz473 mL

Kit Size 1GK (Deionized (D.I) Water)

N/A 72 oz2.13 mL

Kit Size 1QK (44GN060 Base)

N/A 8 oz237 mL

Kit Size 1QK (44GN060CAT)

N/A 4 oz118 mL

Kit Size 1QK (Deionized (D.I) Water)

N/A 18 oz532 mL

Characteristics (At 150% Reduction)

Weight Per Gallon (Base)

N/A 12.33 lb

Weight Per Gallon (Catalyst)

N/A 9.34 lb

Weight Per Gallon (Admixed)

N/A 9.52 lb

Solids by Weight (Base)

N/A 77.1 %

Solids by Weight (Catalyst)

N/A 69.3 %

Solids by Weight (Admixed)

N/A 35.7 %

Solids by Volume (Base)

N/A 58.3 %

Solids by Volume (Catalyst)

N/A 67.2 %

Solids by Volume (Admixed)

N/A 24.5 %

Coatings Volatile Organic Compounds (VOC) (Base)

N/A 334 g/L2.78 lb/gal

Coatings Volatile Organic Compounds (VOC) (Catalyst)

N/A 344 g/L2.87 lb/gal

Coatings Volatile Organic Compounds (VOC) (Admixed)

N/A 337 g/L2.81 lb/gal

Material Volatile Organic Compounds (VOC) (Base)

N/A 334 g/L2.78 lb/gal

Material Volatile Organic Compounds (VOC) (Catalyst)

N/A 344 g/L2.87 lb/gal

Material Volatile Organic Compounds (VOC) (Admixed)

N/A 135 g/L1.13 lb/gal

Theoretical Coverage Per Gallon (1GK) Kit

N/A 393 ft²

Theoretical Coverage Per Gallon (GK) Kit

N/A 983 ft²

Note for Dry Film Density and Theoretical Coverage

N/A Dry film density and theoretical coverage based on proper application of coating at 1 mil dry film thickness and 100% transfer efficiency.

Theoretical Dry Film Weight Per Gallon Kit

N/A 3.92 g/ft²0.00864 lb/ft²

Note for Characteristics

N/A Characteristics are calculated based on product formulas and ingredient characteristics as reported to Deft, Incorporated by raw material suppliers. Values reported are not specification values. They are presented for general information only.

Specifications

Dry Film Density

N/A 1.66 g/cm³

Color

N/A BAC 4910 Green

Dry Time

Maximum Dust Free Time

N/A 15 minutes

Maximum Tack Free Time

N/A 2 hour

Maximum Dry Through Time

N/A 6 hour

Minimum Dry to Tape Time

N/A 4 hour

Maximum Full Cure Time

N/A 7 days

Note for Dry Times

N/A Dry times above were established at room (ambient) temperatures, 75 ºC± 5 ºF and 50% ± 10% Relative Humidity.

Forced Dry Schedule

Forced Dry Schedule

N/A For dry to stack conditions only. Allow a minimum of 15 minutes flash off time at ambient temperatures prior to exposing painted parts to high temperatures. Complete testing should be done prior to use. Below are suggested starting points. Other variables may affect these cure schedules. As a general guideline Max Operating Temperature (MOT) is 275 ºF or less. This is a general guideline only, not experimental data. End user must confirm that this product is fit for use at elevated temperature-time profiles.

Flash Off Time at 120 Degree Fahrenheit (ºF) Temperature

N/A 90 minutes

Flash Off Time at 140 Degree Fahrenheit (ºF) Temperature

N/A 60 minutes

Flash Off Time at 160 Degree Fahrenheit (ºF) Temperature

N/A 40 minutes

Flash Off Time at 180 Degree Fahrenheit (ºF) Temperature

N/A 30 minutes

Note for Flash Off Time

N/A Ambient temperatures are defined as 70 ºC ± 10 ºF and 50% ± 10% relative humidity.

Mixing and Thinning

Mixing and Thinning

N/A GK: Add the catalyst to the base component and shake for 5 minutes. Pour out into a separate container such as a pressure pot. Fill the original container from the catalyzed material with DI or Distilled water and shake or stir. Add ½ of this water to the catalyzed material while stirring. When stirred in, add the other ½ container of water while stirring. Fill this container ½ full and add it while stirring. This 150% water addition will yield a viscosity of approx 20 ± 2 seconds in #2 EZ Zahn cup. Add small amounts of water if necessary to achieve this viscosity. A slight variation in water is normal. Product can accept 175% water reduction. 1GK &1QK: Add the entire catalyst component to the base component. Fill the can to approximately the bottom of the chime with distilled or deionized water Secure the can lid and place on paint shaker in an inverted position for 10 - 15 minutes.

Application Equipment

Application Equipment

N/A Conventional, Air, Air Assisted Airless, HVLP, Electrostatic spray equipment may be used to apply this material. For your application, please contact the equipment manufacturer for more specific information on Conventional, HVLP or Electrostatic spray applications, and recommendations on hose diameter and lengths.

Packaging, Yields, Shipping Weight

Kit Size GK Approximately Yield (Mixed)

N/A 2.5 gal9.5 L

Kit Size GK Approximately Shipping Weight

N/A 13.5 lb6.1 kg

Kit Size 1GK Approximately Yield (Mixed)

N/A 1 gal3.8 L

Kit Size 1GK Approximately Shipping Weight

N/A 5.7 lb2.6 kg

Kit Size 1QK Approximately Yield (Mixed)

N/A 1 dry qt946 mL

Kit Size 1QK Approximately Shipping Weight

N/A 1.9 lb861 kg

Note for Kit Sizes

N/A This material is available in the follow kit sizes

Features

Features

N/A
  • Corrosion Inhibiting
  • Chemical and Solvent Resistant
  • Resistant to Hydraulic Fluids, Lubricating Oils, Phosphate Ester Based Hydraulic Fluids and Distilled Water

Equipment Cleanup

Equipment Cleanup

N/A Water will clean approximately 95% of liquid primer remaining on equipment. Follow with Deft's IS-248 Cleaning Solvent for Water Reducible Primer to remove any residual primer from equipment. Once material has cured, use an approved chemical paint removal system to strip primer from parts and equipment

Safety

Safety

N/A Refer to the product label or Material Safety Data Sheet (MSDS) for each component for Personal Protective Equipment and Proper Handling.
  • 1 At 72 Degree Celsius (ºC) ± 2 Degree Fahrenheit (ºF)