01F Series are chemically cured, two-component, high solids epoxy topcoats for use on aircraft and aerospace equipment.
  • Volatile organic hazardous air pollutants-free (VOHAP-free)
  • When used over properly applied commercial or military primers, provides excellent adhesion and flexibility
  • Resistant to immersion in hydraulic fluids, lubricating oils and water
Unit of Measure

Components

Components

N/A Mix Ratio (by Volume)
  • 01F Series (base component) - 3 Part
  • 80X109F (catalyst component) - 1 Part

Kit Size (Yield (Mixed))

N/A 2 gal2 dry qt

Specifications

Specifications

N/A 01F Series is qualified to:
  • MIL-PRF-22750 Type II Class H
    Grade A
Note: PPG Aerospace recommends you check the most recent specification QPLs for updated information.

Product Compatibility:

01F Series is compatible with the following topcoat specifications:
  • MIL-DTL-53022
  • MIL-DTL-53030
  • MIL-PRF-23377
  • MIL-PRF-85582

Surface Preparation and Pretreatments

N/A 01F Series epoxy topcoats can be applied over clean, dry, intact primed surfaces.

Shelf Life

N/A 12 months from date of manufacture per MIL-PRF-22750
24 months from date of manufacture for Deft Standard
Note: Shelf life is provided for original, unopened containers

Color

N/A Available in Federal STD 595C and other color standards

Instructions for Use

Mixing Instructions

N/A Thoroughly stir or shake the base component (Part A) before combining to ensure all solids are completely dispersed. Add one volume of catalyst component (Part B) to the three parts of base component (Part A). Do not use the catalyst component (Part B) from another color. Mix by hand stirring, paint shaker or mechanical mixing to ensure the base/catalyst mixture is homogeneous. Do not shake or mechanically mix material for longer than 10 minutes. Thinners are not required for the mixed material. If the addition of a thinner is necessary, MIL-T-81772B Type II* (IS-237) is available. Do not add thinner to attempt to compensate for coatings beyond its useful pot life.

Note: Use only if needed and if local and state VOC limits allow.

Note: It is important to condition the paint for 24 hours prior to mixing by placing all materials in the shop or hangar, with ambient temperatures between 13 ºC and 35 ºC (55 ºF to 95 ºF). The minimum temperature of the paint components should be 13 ºC (55 ºF) prior to mixing.

Induction Time Required at 21 to 27 Degree Celsius (ºC) (70 to 80 Degree Fahrenheit (ºF)) Temperature

N/A 30 minutes

Maximum Viscosity at 23 Degree Celsius (ºC) (73 Degree Fahrenheit (ºF)) Temperature (#4 Ford Cup)

N/A 50 seconds

Note for Viscosity

N/A Viscosities quoted are typical values obtained when using specified mix ratio.

Pot Life at 21 to 25 Degree Celsius (ºC) (70 to 77 Degree Fahrenheit (ºF)) Temperature

N/A 4 hour

Application Guidelines

Recommended Application Conditions - Temperature

N/A 15 to 30 ºC59 to 86 ºF

Recommended Application Conditions - Relative Humidity (RH)

N/A 20 to 90 %

Applications

N/A Coating may be applied over properly cleaned composite surfaces, and epoxy primer coatings. Apply the topcoat by spray, using two coats to a total dry film thickness of 1.7 to 2.3 mils. Apply the first coat as a light (mist) coat. Allow the coat to set for at least 15 minutes (depending on airflow, temperature and humidity) before applying the second coat to permit solvent evaporation. Apply the second coat in a full wet coat to achieve the desired film thickness.

These application guidelines represent PPG's best advice in standard conditions. Some parameters will be influenced by environmental conditions, equipment settings, and other variables.

Theoretical Coverage at 25 Microns (µm) Dry Film Thickness

N/A 82 m²/L

Theoretical Coverage at 1 Mil Dry Film Thickness

N/A 890 ft²/gal

Recommended Dry Film Thickness

N/A 43 to 58 c1.7 to 2.3 mil

Dry Film Density

N/A 1.31 g/cm³10.93 lb/gal

Dry Film Weight at 25 Microns (µm) Dry Film Thickness

N/A 4.0 g/m²

Dry Film Weight at 1 Mil Dry Film Thickness

N/A 0.00888 lb/ft²

Equipment

Equipment Type1 N/A Conventional Air Spray Gun Electrostatic Air Assisted Airless Spray Gun Electrostatic Air Spray Gun High Volume Low Pressure Spray Gun (HVLP)

Tip Size for Electrostatic Air Spray Gun

N/A 1.2 mm1.5 mm

Tip Size for Electrostatic Air Assisted Airless Spray Gun

N/A #611 #613 (Graco Nomenclature)

Tip Size for High Volume Low Pressure Spray Gun (HVLP)

N/A 1.0 to 1.4 mm

Tip Size for Conventional Air Spray Gun

N/A 1.2 to 1.8 mm

Pot Pressure for Electrostatic Air Spray Gun

N/A 10 to 20 psi0.69 to 1.4 bar

Pot Pressure for Electrostatic Air Assisted Airless Spray Gun

N/A 700 to 1200 psi48 to 82 bar

Pot Pressure for High Volume Low Pressure Spray Gun (HVLP)

N/A 10 to 20 psi0.69 to 1.4 bar

Pot Pressure for Conventional Air Spray Gun

N/A 10 to 20 psi0.69 to 1.4 bar

Atomization Pressure at the Cap for Electrostatic Air Spray Gun

N/A 45 to 60 psi3.1 to 4.1 bar

Atomization Pressure at the Cap for Electrostatic Air Assisted Airless Spray Gun

N/A 40 to 60 psi2.8 to 4.1 bar

Maximum Atomization Pressure at the Cap for High Volume Low Pressure Spray Gun (HVLP)

N/A 10 psi0.69 bar

Maximum Atomization Pressure at the Cap for Conventional Air Spray Gun

N/A 45 to 60 psi3.1 to 4.1 bar

Equipment Cleaning

N/A Clean spray equipment as soon as possible after use. Flush spray equipment with IS-237 Epoxy Reducer (MIL-T-81772B Type II) may be used for general cleanup of parts and equipment before coating has fully cured and is still in a liquid state. Once material is fully cured, use an approved chemical paint removal system to strip off coating.

Physical Properties

Gloss

N/A Available in flat semi-gloss and full gloss

Minimum Set to Touch Dry Time at 21 to 27 Degree Celsius (ºC) (70 to 80 Degree Fahrenheit (ºF)) Temperature

N/A 4 hour

Minimum Dry to Tape Time at 21 to 27 Degree Celsius (ºC) (70 to 80 Degree Fahrenheit (ºF)) Temperature

N/A 8 hour

Maximum Dry Hard Time at 21 to 27 Degree Celsius (ºC) (70 to 80 Degree Fahrenheit (ºF)) Temperature

N/A 8 hour

Full Cure Dry Time at 21 to 27 Degree Celsius (ºC) (70 to 80 Degree Fahrenheit (ºF)) Temperature

N/A 7 days

Note for Dry Times

N/A Dry times above were established at room (ambient) temperatures, 70 ºC ± 10 ºF and 50% ± 10% relative humidity.

Forced Dry Schedule

N/A For dry to stack conditions only. Allow a minimum of 15 minutes flash off time at ambient temperatures prior to exposing painted parts to high temperatures. Complete testing should be done prior to use. Below are suggested starting points. Other variables may affect these cure schedules.

Flash Off Time at 49 Degree Celsius (ºC) (120 Degree Fahrenheit (ºF)) Temperature

N/A 45 minutes

Flash Off Time at 60 Degree Celsius (ºC) (140 Degree Fahrenheit (ºF)) Temperature

N/A 30 minutes

Flash Off Time at 71 Degree Celsius (ºC) (160 Degree Fahrenheit (ºF)) Temperature

N/A 20 minutes

Flash Off Time at 82 Degree Celsius (ºC) (180 Degree Fahrenheit (ºF)) Temperature

N/A 15 minutes

Note for Flash Off Time

N/A Ambient temperatures are defined as 70 ºC ± 10 ºF and 50% ± 10% relative humidity.
Maximum Volatile Organic Compounds (VOC) Volume2 N/A 340 g/L

Test Method for Volatile Organic Compounds (VOC)

N/A Environmental Protection Agency (EPA) Method 24

Flash Point Closed Cup Base Component Temperature

N/A -20 ºC-4 ºF

Flash Point Closed Cup Catalyst Component Temperature

N/A 22 ºC72 ºF

Storage Recommendations

Storage Recommendations

N/A Inspect the condition of the container to ensure compliance. The material should be stored at temperatures between 5 ºC to 35 ºC (41 ºF to 95 ºF to ensure shelf life.

Note: When procuring to a qualified material specification, follow those storage instructions.

Health Precautions

Health Precautions

N/A This product is safe to use and apply when recommended precautions are followed. Before using this product, read and understand the Safety Data Sheet (SDS), which provides information on health, physical and environmental hazards, handling precautions and first aid recommendations. An SDS is available on request. Avoid overexposure. Obtain medical care in case of extreme overexposure.

Additional Information

Additional Information

N/A
  • Provides excellent chemical resistance to solvents
  • Volatile organic compounds (VOC)< 340 g/l (2.8 pounds/gallon)
  • Rated up to 121 ± 3 ºC (250 ± 5 ºF)

Note

Note

N/A The application and performance property values above are typical for the material, but not intended for use in specifications or for acceptance inspection criteria because of variations in testing methods, conditions and configurations.

For industrial use only. Keep away from children.

All recommendations, statements, and technical data contained herein are based on tests we believe to be reliable and correct, but accuracy and completeness of said tests are not guaranteed and are not to be construed as a warranty, either expressed or implied. User shall rely on his own information and tests to determine suitability of the product for the intended use and assumes all risks and liability resulting from his use of the product. Seller's and manufacturer's sole responsibility shall be to replace that portion of the product of this manufacturer which proves to be defective. Neither seller nor manufacturer shall be liable to the buyer or any third person for any injury, loss, or damage directly or indirectly resulting from use of, or inability to use, the product. Recommendations or statements other than those contained in a written agreement signed by an officer of the manufacturer shall not be binding upon the manufacturer or seller.
  • 1 01F Series are compatible with all current forms of spray equipment.
  • 2 Mixed, ready to use VOC